Dynamic Field Response Studies and Earthauqke Instrumentation of the Meloland Road Overcrossing
Ambient vibration data was obtained at the Meloland Road Overcrossing near El Centro in California by The California Department of Transportation (CALTRANS) as part of a 1978 Federal Highway...

A General Hysteresis Model for Wood Structures
To predict the dynamic response of a wood structure, its energy dissipation mechanism and hysteresis behavior must be appropriately modeled. This paper presents a new hysteresis model...

Wind Loads on Arena Roofs Using Aerodynamic Models
The concept behind an aerodynamic wind tunnel model used to predict dynamic response to wind excitation is the generalized load in a particular natural mode of vibration is measured ,...

85 Stories in Kuala Lumpur?The 5th and 6th Tallest Buildings in the World
A concrete core and cylindrical concrete tube structure provides a safe, elegant, efficient and constructible solution to the challenge of designing the world's 5th and 6th tallest buildings,...

Predicting Turbine-Generator Foundation Vibrations
Two of the major considerations in the design of large turbine-generator foundations are to maintain the proper shaft alignment and to limit the vibration of the machine during operation....

Dynamic In-Plane Racking Tests of Curtain Wall Glass Components
This paper is concerned with the seismic performance of 'architectural.' or 'non-structural' building elements such as glass elements in curtain wall systems. A pilot study was undertaken...

Response of Equipment in Structures Supported on Resilient-Friction Base Isolators Subjected to Ground Motion
In this paper, the response of equipment in structures on a particular friction-type device, the resilient-friction base isolator, is examined. The R-FBI is composed of layers of Teflon...

Robust Control for Buildings Under Earthquake
Robust control techniques are applied to civil engineering structures subjected to earthquake excitation. Full state feedback and observer based control laws are used to reduce the response...

Fluid Viscous Damper for Improving the Earthquake Resistance of Buildings
Experimental results are presented which demonstrate that the use of fluid dampers as add-on devices in moment resisting frames substantially increases damping and reduces seismic story...

Seismic Performance of Base-Isolated Building Structures
The theories and assumptions behind the base isolation technology are briefly described. As an illustration of its application, the base isolation of an existing 12-story hospital in Long...

Neural Networks in Structural Control
Let the response of a simple two-story frame to a stochastic dynamic excitation be controlled by activating suitable actuators. A neural network is trained to recognize, from the measurement...

Development of Bridge Load Model for LRFD Code
The load models are based on the available statistical data on dead load, truck loads and dynamic loads. The paper deals mostly with the static live load. The model is derived from truck...

Dynamic Inelastic Analysis of Tall Buildings
Members with undesirably early formed plastic hinges as well as excessive conservatism introduced in the preliminary design of tall buildings can be identified by the behavior state study...

Reliability-Based Design of Transmission Towers Under Wind and Ice Loadings
This study suggests a practical but rational approach for the development of reliability-based LRFD criteria for transmission towers under wind and ice loadings in Korea. Based on available...

Nonlinear Dynamic Analysis of Single Point Moored Buoy Under Wave and Current Loadings
In this study, a single point moored spherical buoy under wave and current loadings is analyzed in the time domain considering time memory effects. Geometric nonlinearity of the mooring...

Nonlinear Dynamic Analysis of Structural Frames Using Reduced Order Models
In order to provide more realistic and economical design of large structures it is necessary to perform analyses which take into account both material and geometric nonlinearities. Unfortunately,...

Three-Dimensional Analysis Model for Complete Masonry Buildings
For the predictive and diagnostic analysis of the complete nonlinear response of masonry buildings to seismic load input, a 3-D finite element model is under development at UCSD. The model,...

New Views for Modeling Dynamic Response of URM Buildings
Various computational models are used to depict seismic response of an unreinforced masonry building that was subjected to the 1989 Loma Prieta Earthquake. The worthiness of various analytical...

Dynamic Response of Variable Height Retaining Walls
A full-scale dynamic test was conducted on a 140 ft long reinforced concrete retaining wall. The observed resonant configurations were similar to those of a cantilever plate and showed...

Ambient Vibration Survey: Sunshine Skyway Bridge
An ambient vibration survey of the Sunshine Skyway Bridge was performed. The goal of this survey was to provide field data on the dynamic characteristics of the structure to corroborate...

 

 

 

 

Return to search